Notes for Installation of LED Industrial and Mining Luminaries

Publication time:2019/2/23 15:17:28

In order to ensure the smooth progress of workers'production and inspection work, it is necessary to equip corresponding lighting fixtures in the workshop to meet the brightness requirements of workers' work. So the application of LED industrial and mining lamp is more and more in industry and other places. It belongs to industrial electronic products. It needs to be fixed to the designated position in the use process. But this involves the installation of LED industrial and mining lamp. What are the matters needing attention in the installation of LED industrial and mining lamp?

First, before installation, the integrity of LED industrial and mining lamps and complete accessories must be checked.

Second, when installing the LED industrial and mining lamps, the installation personnel must hold professional electrician's certificate, so as to avoid the damage of the LED industrial and mining lamps caused by installation errors.

Third, the connection on the LED industrial and mining lamp can be fixed by wire clamp through the borehole and the connection behind the lamp, so as to ensure that the fixture is firm.

Fourthly, we should ensure that the power cord of the LED industrial and mining lamps has enough length, not to be subjected to tension or tangential force, avoid excessive tension when installing the connection of the LED industrial and mining lamps, do not make the connection knot, pay attention to distinguishing the output connection, and do not confuse with other lamps and lanterns.

Fifthly, the distance between LED industrial and mining lamps and flammable materials should be at least 0.2 m, and the gap between the installed ceiling and the wall should be 2 cm high. The LED industrial and mining lamps should not be all installed in the ceiling or beside the wall with heat source. Attention should be paid to the separation of low-voltage and high-voltage wiring.

Sixth, after the installation of LED industrial and mining lights, electrical testing is also needed. If individual LED industrial and mining lights can not be lit, it needs to check the circuit or the problem of LED industrial and mining lights. After ensuring the normal lighting of all LED industrial and mining lights, the installation of LED industrial and mining lights is completed.